Input / Output Ratings
Note: Maximum continuous total DC output power should not exceed 350W. |
Features, General Spec., Agency Requirements
Features | General Specifications | Agency Requirements |
★Universal Input, active PFC ★Hot-Swap / Hot-Plug application ★Automatic FAN speed control ★Power failure alarm & signals ★Power status LED indecator ★OVP[Over Voltage Protection] ★UVP[Under Voltage Protection] ★OCP[Over Current Protection] ★OPP[Over Power Protection] ★OTP[Over Temperature Protection] ★MTBF>100,000 hours ★3 years warranty |
★Input voltage range: 100-240V/±10% ★Power factor: minimum 0.95/full load ★Efficiency: meet 80+ Bronze ★PG: 100-500ms, TTL type signal ★PSON: TTL type signal ★Operating temperature: 0-45℃ ★Operating humidity: 20-90% |
★Harmonic: EN61000-3-2 ★Certification EMI/RFI: CE, FCC clase A, CISPR class A ★Certification safety: UL/cUL, CB, TUV, CCC |

Electrical Specification
Regulation, Ripple & Noise |
|||||
Output Voltage | +5V | +3.3V | +12V | -12V | +5VSB |
Load Regulation | ±5% | ±5% | ±5% | ±5% | ±5% |
Cross Requlation | ±5% | ±5% | ±5% | ±5% | ±5% |
Line Regulation | ±1% | ±1% | ±1% | ±1% | ±1% |
Ripple & Noise | 50mV | 50mV | 120mV | 120mV | 50mV |
|